RAM Foundation
|
|
General
- Fully supports the ACI-318 and BS8110 design codes and numerous building codes including IBC2006, IBC 2003/2000, UBC 97, SBC 99 and BOCA 96/99
- Automatically generates code required load combinations for both soil bearing checks and concrete design, and allows for user-defined custom load combinations
- Flexible user-defined optimization parameters allow you to reach a design based on your standards and preferences
- Design process is fully interactive so changes can be made and the effect reported instantaneously
- Allows for automatic optimization or user controlled design of both foundation dimensions and reinforcing
- Sizes footings for uplift automatically, including user input safety factor
- Reinforcing designs conform to all code standards and limits including reinforcement ratio, spacing, development length, and cover
- Produces complete and attractive design calculations
- Produces foundation plan drawings, foundation details and schedules for CAD
Spread Footings
- Fast and accurate solution for spread footings with axial loads and bi-axial moments, taking into account no-tension behavior of soil
- Checks the limit states of one-way beam shear, punching shear accounting for moments in columns or walls, and footing flexural strength
- Flexural reinforcement automatically selected for spread footings, with user-override capabilities
- Spread footings may be designed for either true loading or soil capacity
- Negative flexural reinforcement (top bars) automatically provided when required
- Allows you to reduce the number of unique spread footings with option to use controlling reinforcement on all footings of the same size
- Ability to add spread or pile cap foundations under columns located at the end of shear walls and continuous footings under the shear walls
Continuous Footings
- Allows unlimited number of columns, braces, and walls on a continuous footing
- Fast finite element analysis for continuous footings, taking into account no-tension behavior of soil
- Shear and flexural reinforcement automatically selected for continuous footings
- Options to override reinforcement sizes or quantity along any part of continuous footings
- Interactive diagram of provided and required moment/shear envelopes in continuous footing View/Update dialog
Pile Caps
- Fast and accurate solution for pile caps with axial loads, bi-axial moments, shear, and torsion
- Comprehensive pile cap check including column punching shear, single pile and double pile punching shear, as well as one-way shear
- Pile capacity check for compression, tension, and shear
- Pile caps may be designed for either true pile loads or pile capacity
- Negative flexural reinforcement (top bars) automatically provided when required
- Truss theory considered when required by BS8110-97 code
|
|
|