LEAP RC-PIER Latest Release
|
New Features in LEAP RC-PIER v.9.0.0
- Stepped cap: Users can now define stepped caps for piers. Program provides two options to compute the step thickness using start and end elevations or to input step thickness manually.
- Custom load combinations: Program provides two options:
1. Generate default combinations. 2. Define your own combination selecting individual load case and factor.
-
Analysis filter: User has the ability to filter out analysis results based on member and node number selection.
-
Check point for flexure and shear design: In cap design, the users can now define separate design check points for flexure and shear.
-
Ability to define footing eccentricity in both X and Z directions.
-
A new grid format for loads data allows importing loads from CSV file type. Also, allows copy/paste from and to Excel spreadsheets.
-
In previous version, stem wall was assumed to be concentric with the footing. In v9.0, this limitation has been removed and users can now define eccentric stem walls.
-
Program now has new pile section library.
-
Footing dialog is improved to help user easily define footing/eccentricity dimensions.
|
|